Download System PDF

TitleSystem
File Size2.0 MB
Total Pages234
Table of Contents
                            Cover
Remarks
Table of Contents
INTRODUCTION
	PURPOSE
	OUTLINE OF THIS MANUAL
	TERMS IN THIS MANUAL
		PBX System Designation
		Terminal Name
	REFERENCE MANUAL
Chapter 1 GENERAL INFORMATION
	SYSTEM OUTLINE
	STATION-TO-STATION CONNECTION
	PUBLIC NETWORK/TIE LINE NETWORK CONNECTION
	CCIS CONNECTION
	SIP CONNECTION
	SYSTEM CONDITIONS
		Conditions for Overall System
		Conditions for IP Station
		Conditions for Peer-to-Peer Connection
		Conditions for Public Network/Tie Line Network Connection
		Conditions for CCIS Connection
		Conditions for VoIPDB
		Conditions for SIP Connection
		Conditions for DRS
		Conditions for Legacy Interface (LT/AP)
		Conditions for Maintenance
	SERVICES
		Business/Hotel/Data/CCIS/ISDN/WCS
		OAI
Chapter 2 INSTALLATION
	PRECAUTIONS
		Grounding Requirements
		Static Electricity Guard
		Turning Power ON
		Turning Power OFF
	REQUIRED EQUIPMENT
	INSTALLATION PROCEDURE
		LAN Cable Connection
Chapter 3 SYSTEM DATA PROGRAMMING
	HOW TO READ THIS CHAPTER
	PRECAUTIONS
		System Data Backup
	PROGRAMMING PROCEDURE
	BASIC DATA SETTING
		System Data Memory All Clear
		License Activation Data Loading
		Setting System Clock
		Setting Nation Code
		Setting A-law/µ-law
		Setting Kind of Tone/Music on Hold/Tone
		VLAN Data Assignment
	IP STATION DATA ASSIGNMENT
		IP Station Data Assignment
		IP Station Login/Logout Data Assignment
		SIP Multiline Terminal Protection Mode Data Assignment
	IP STATION SETUP
		IP Multiline Terminal Setup
		SIP Multiline Terminal Setup
	IP STATION LOGIN/LOGOUT OPERATION
		IP Station Login
		IP Station Logout
	IP-PAD DATA ASSIGNMENT
	IPT (P2P CCIS) DATA ASSIGNMENT
		Programming Procedure for IPT (P2P CCIS)
		IPT (P2P CCIS) Data Assignment
	LOCATION DATA ASSIGNMENT
	IP FEATURE PROGRAMMING
		Automatic Program Download for IP Station
		Bandwidth Control
		Call Forwarding-Logout (IP Multiline Terminal)
		FAX over IP
		Modem over IP
		SNMP
		Terminal Login via NAT
	SIP TRUNK DATA ASSIGNMENT
		Programming Procedure for SIP Trunk
		SIP Trunk Data Assignment
		Ringing Tone
	SIP FEATURE PROGRAMMING
		Caller ID Display
		Direct Inward Dialing (DID)
		Registration Number “+” Addition/Deletion
		Fault Registration
		Fragmented IP Packet Receiving
		Session Timer
		NAT Support in SIP Trunk
		Out-band DTMF
	SYSTEM DATA BACKUP
	SYSTEM RESET
Appendix A SYSTEM SPECIFICATIONS
	SYSTEM SPECIFICATIONS
	IP SPECIFICATIONS
Appendix B VOICE QUALITY MEASURES IN VoIPDB
	COUNTERMEASURES FOR ECHO
	COUNTERMEASURES FOR OTHERS
Appendix C TCP/UDP/RTP PORT NUMBER CONDITIONS
	TCP/UDP/RTP PORT NUMBER CONDITIONS
                        
Document Text Contents
Page 1

System Manual

NWA-033621-001
ISSUE 2.0

Page 2

LIABILITY DISCLAIMER

NEC Infrontia Corporation reserves the right to change the specifica-
tions, functions, or features, at any time, without notice.

NEC Infrontia Corporation has prepared this document for use by its
employees and customers. The information contained herein is the
property of NEC Infrontia Corporation and shall not be reproduced
without prior written approval from NEC Infrontia Corporation.

Dterm is registered trademarks of NEC Corporation.
PCPro is a trademark of NEC Corporation.

Copyright 2008

NEC Infrontia Corporation

Page 117

Chapter 3 SYSTEM DATA PROGRAMMING

3-75 NWA-033621-001 Rev.2.0
90ch3001.fm

LOCATION DATA ASSIGNMENT

DESCRIPTION DATA

Specify the Type of Service (TOS) field prece-
dence of the control packet for the IP Station-
to-system to each location number assigned by
CM12 Y=39, 50.

NOTE: The TOS between the IP Station and
the system is determined by this data
setting.


(1)
(2)

Y=14
00-63: Location No.
0-7 : PRECEDENCE 0-7 for control

packet
NONE : 6

Specify the DiffServ Code Point (DSCP) of the
control packet for IP Stations to each location
number assigned by CM12 Y=39, 50.

NOTE: The TOS field precedence that is set
by CM67 Y=14 is invalid when this
data is set.


(1)
(2)

Y=15
00-63: Location No.
00-FF : DSCP of control packet for IP

Station
NONE : C0

F

CM67

G

Page 118

Chapter 3 SYSTEM DATA PROGRAMMING

3-76 NWA-033621-001 Rev.2.0
90ch3001.fm

LOCATION DATA ASSIGNMENT

DESCRIPTION DATA

Specify the original CODEC list to the system,
if required.
To provide the original CODEC list, assign the
CODEC type and payload size to CODEC list
0-3.

(1)

(2)

100-103: Priority 1-4 in CODEC list 0
120-123: Priority 1-4 in CODEC list 1
140-143: Priority 1-4 in CODEC list 2
160-163: Priority 1-4 in CODEC list 3
01 : G.711 µ-law 64k
02 : G.711 A-law 64k
03 : G.723.1 (5.3/6.3k) NOTE 1
04 : G.729a
07 : G.722 (Wide Band Codec)

NOTE 2
NONE : No data

(1)

(2)

110-113: Priority 1-4 in CODEC list 0
130-133: Priority 1-4 in CODEC list 1
150-153: Priority 1-4 in CODEC list 2
170-173: Priority 1-4 in CODEC list 3
01-04 : 10 ms.-40 ms. NOTE 3
NONE : No data

NOTE 1: G.723.1 is not available when using DT700 Series and VoIPDB (IP-PAD/IPT [P2P CCIS]/
SIP trunk).

NOTE 2: G.722 (Wide Band Codec) is available only when using DT700 Series or VoIPDB (IP-PAD/
IPT [P2P CCIS]/SIP trunk).

NOTE 3: The following payload size can be assigned for each CODEC type.
G.711 : 10 ms./20 ms./30 ms./40 ms.
G.722 : 10 ms./20 ms./30 ms./40 ms.
G.723.1 : 30 ms fixed
G.729a : 10 ms./20 ms./30 ms./40 ms.

NOTE 4: When the payload size setting differs from that for the opposite VoIPDB, the shorter size is
adopted.

G

CM42

END

Page 233

C-5 NWA-033621-001 Rev.2.0
90apc001.fm

TCP/UDP/RTP PORT NUMBER CONDITIONS

For SIP Trunk

PORT
TYPE

DESTINATION
DEFAULT
PORT No.

REMARKS
NUMBER OF
PORT USED

REFERENCE
PAGE

Port for
SIP
control
(UDP)

VoIPDB
(SIP Trunk)

5060 1024-65534
Assigned by CM0B
Y=101>36

1 Page 3-136

JULY/18/2008

Page 234

C-6 NWA-033621-001 Rev.2.0
90apc001.fm

THIS PAGE LEFT BLANK INTENTIONALLY.

JULY/18/2008

Similer Documents