Download GENEX Probe User Guide-(V200R003_04) PDF

TitleGENEX Probe User Guide-(V200R003_04)
TagsGraphical User Interfaces Lte (Telecommunication) Wi Max Microsoft Windows Server (Computing)
File Size3.5 MB
Total Pages525
Table of Contents
                            About This Document
Contents
Figures
Tables
1 New Features of the Probe V200R003
	1.1 New Features of the Probe V200R003C01
	1.2 New Features of the Probe V200R003C00
2 Overview of the Probe
	2.1 Introduction to the Probe
	2.2 Basic Concepts of the Probe
	2.3 Main Interface of the Probe
	2.4 Working Mode of the Probe
	2.5 Recommended Device List
		2.5.1 Recommended Terminal List (GSM/WCDMA)
		2.5.2 Recommended Terminal List (LTE)
		2.5.3 Recommended Terminal List (WiMAX)
		2.5.4 Recommended Scanner List
3 Installing the Probe
	3.1 Preparations Before Installing the Probe
	3.2 Installing Shared Components
	3.3 Installing the Probe Main Program
	3.4 Plugging in a Dongle
4 Starting the Probe
5 Managing the Map Window
	5.1 Basic Concepts About Maps
	5.2 Importing Maps
		5.2.1 Importing Outdoor Test Maps
		5.2.2 Importing Indoor Test Maps
	5.3 Adding Layers
	5.4 Configuring Layer Properties
	5.5 Configuring Legend Properties
6 Managing Engineering Parameters
	6.1 Engineering Parameters Supported in Different Network Systems
	6.2 Importing Engineering Parameters
7 Connecting External Devices
	7.1 Connectable External Devices
	7.2 Plugging in External Devices
	7.3 Configuring External Devices
		7.3.1 Configuring External Devices Automatically
		7.3.2 Configuring External Devices Manually
	7.4 Enabling External Devices
	7.5 Selecting the Data to Be Collected
	7.6 Configuring Device Alarms
8 Collecting Data
	8.1 Data Collection Process
	8.2 Preparations Before Data Collection
	8.3 Creating a Project
	8.4 Designing Test Plans
	8.5 Performing a Test Plan
		8.5.1 Setting the APN (GSM/WCDMA)
		8.5.2 Performing an Indoor Test
		8.5.3 Performing an Outdoor Test
		8.5.4 Monitoring the Test
		8.5.5 Stopping Test Plans
9 Managing Logfiles
	9.1 Recording Logfiles
	9.2 Segmenting Logfiles
	9.3 Replaying Logfiles
	9.4 Exporting Logfiles
10 Managing View Windows
	10.1 Presentation of IEs and Events
	10.2 Browsing Data
	10.3 Configuring the View Window
		10.3.1 Configuring the Line Chart View
		10.3.2 Configuring the List View
		10.3.3 Configuring the Chart View
		10.3.4 Configuring the Plain Text View
11 Typical Application
	11.1 Speech Quality Evaluation Tests (GSM/WCDMA)
		11.1.1 Synchronous Speech Quality Evaluation Test
		11.1.2 Asynchronous Speech Quality Evaluation Test
		11.1.3 Speech Quality Evaluation Test Between PHU Terminal and PSTN
SQE Server
	11.2 Forcing Function Tests
		11.2.1 Setting the GSM Nonvolatile Parameters
		11.2.2 Conducting GSM C/A Measurements
		11.2.3 Conducting GSM Frequency Scanning
		11.2.4 Conducting the GSM Forcing Function Test
		11.2.5 Conducting the WCDMA Forcing Function Test
		11.2.6 Conducting the LTE Forcing Function Test
	11.3 IP Analysis
12 Interface Reference of the Probe
	12.1 Interface Description: Test Plan Control Window
	12.2 Interface Description: Engineering Parameter management Window
	12.3 Interface Description: OutdoorMap Window
	12.4 Interface Description: IndoorMap Window
	12.5 Interface Description: Test Data View
	12.6 Interface Description: Line Chart View
	12.7 Parameters for Configuring External Devices
	12.8 Parameters for Filtering the Original Data
	12.9 Parameters for Configuring the Test Items
	12.10 Parameters for Monitoring the Test
	12.11 Parameters for Importing the Engineering Parameters
	12.12 Parameters for Importing the Outdoor Raster Map
	12.13 Parameters for Configuring the Legend Properties
	12.14 Parameters for Configuring the Layer Control Properties
	12.15 Parameters for Setting the Predefined Event
	12.16 Parameters for Configuring the Device Alarm
	12.17 Parameters for Setting IE Audio Indications
	12.18 Parameter for Other System Settings
	12.19 Parameters for Configuring the Properties of the List Views
	12.20 Parameters for Configuring the Properties of the Line Chart
View
	12.21 Parameters for Testing the Forcing Feature of the GSM
	12.22 Parameters for WCDMA Forcing Feature Test
	12.23 Parameter Description: LTE Forcing Feature Test
	12.24 Parameters for Performing the C/A Measurement of the GSM
	12.25 Parameters for Exporting the Data
	12.26 Parameters for Configuring the Data Export Format of the Scanner
13 FAQs
	13.1 Problems Related to Software Start
		13.1.1 What Should I Do When the Verification of the Dongle Fails?
		13.1.2 What Should I Do When the License Check Fails?
		13.1.3 How to Install the East Asian Language Package?
		13.1.4 How to Uninstall the Main Program
		13.1.5 How to Uninstall the GENEX Shared Components
	13.2 Problems Related to Device Connections
		13.2.1 What Should I Do When the Probe Searching for the MS Fails?
		13.2.2 What Should I Do When the Probe Searching for the Scanner Fails?
		13.2.3 What Should I Do When the Probe Searching for the GPS Fails?
		13.2.4 What Should I Do When the Mouse Becomes Invalid After the GPS
Is Connected to the PC?
		13.2.5 What Should I Do When the PCTel DTI Scanner Fails to Receive
the GPS Signals?
		13.2.6 How to Configure an LTE UE?
	13.3 Problems Related to Views
		13.3.1 What Should I Do When Opening the Map View Fails?
		13.3.2 What Should I Do When Opening the Chart View Fails?
		13.3.3 What Should I Do When Importing Engineering Parameters Fails?
		13.3.4 What Should I Do If No Data Is Displayed in the WCDMA View
Windows?
	13.4 Problems Related to Tests
		13.4.1 What Should I Do When FTP Service Tests Fail?
		13.4.2 What Should I Do When Invalid MOS Values Are Generated?
		13.4.3 What Should I Do When UE Fails to Access the Network During
the LTE Forcing Feature Test?
		13.4.4 How to Convert Frequencies into UARFCNs (WCDMA)?
		13.4.5 What Should I Do When the Automatic Answer Setting of Huawei U1251 Is Invalid?
14 Appendix
	14.1 Description of Test Items
		14.1.1 Test Items Supported in Different Networks
		14.1.2 Test Items of MSs
		14.1.3 Test Items of PCTel Scanners
		14.1.4 Test Items of Anritsu Scanners
		14.1.5 Test Items of Rohde & Schwarz Scanners
	14.2 Description of Predefined Events
		14.2.1 General Events
		14.2.2 GSM Predefined Events
		14.2.3 WCDMA Predefined Events
		14.2.4 CDMA Predefined Events
		14.2.5 WiMAX Predefined Events
		14.2.6 LTE Predefined Events
	14.3 Description of Information Elements
		14.3.1 GSM Information Elements of MSs
		14.3.2 WCDMA Information Elements of UEs
		14.3.3 CDMA Information Elements of MSs
		14.3.4 WiMAX Information Elements of UEs
		14.3.5 LTE Information Elements of UEs
		14.3.6 Information Elements of Scanners
		14.3.7 Packet Service Testing Information Elements
		14.3.8 Speech Quality Evaluation Information Elements
		14.3.9 Noise Test Information Elements
	14.4 Keyboard Shortcuts
	14.5 PSTN SQE Server
		14.5.1 Overview of the PSTN SQE Server
		14.5.2 Installing the PSTN SQE Server
		14.5.3 Using PSTN SQE Server
		14.5.4 Interface Reference of the PSTN SQE Server
		14.5.5 FAQs
		14.5.6 Test Items of the PSTN SQE Server
		14.5.7 Predefined Events of the PSTN SQE Server
15 Technical Support
                        
Document Text Contents
Page 1

GENEX Probe
V200R003

User Guide

Issue 04

Date 2011-02-15

HUAWEI TECHNOLOGIES CO., LTD.

Page 262

Property Value/Range/Unit Description

Timeout The value must be a positive integer.
The default value is 30. The unit is
second.

Indicates the timeout time. The
timing starts when the first gateway
connection request is sent. If the
connection is not set up within the
preset time, you can infer that the
connection fails.

IP Contact local network operators to
obtain the IP address.

Indicates the IP address of the WAP
gateway.



WAP Logon (GSM/WCDMA)
This describes the properties of the WAP Logon test item. You can refer to this part when
performing the WAP login test, and then perform the related operations.

You can test the WAP login and upload.

You must perform the Dial Up test before the WAP Logon test.

Property Value/Range/Unit Description

Test Count The value must be a positive integer.
The default value is 10.

Indicates the number of tests.

Test Interval The value must be a positive integer.
The default value is 5. The unit is
second.

Indicates the interval between two
tests.

Timeout The value must be a positive integer.
The default value is 60. The unit is
second.

Indicates the timeout time. The
timing starts when the first gateway
connection request is sent. If the
connection is not set up within the
preset time, you can infer that the
connection fails.

URL The URL starts with http://. Indicates the URL of the tested WAP
page.

Download
Icon

You can select the following values:
l True: downloads icons on the

title page.
l False: not download icons on the

title page.
The default value is True.

Indicates whether to download icons
on the title page.

IP Contact local network operators to
obtain the IP address.

Indicates the IP address of the WAP
gateway.

Port The value ranges from 0 to 1023, and
the default value is 80.

Indicates the port number of the
WAP.



14 Appendix
GENEX Probe

User Guide

14-52 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.

Issue 04 (2011-02-15)

Page 263

WAP Page Refresh (GSM/WCDMA)

This describes the properties of the WAP Page Refresh test item. You can refer to this part
when performing the WAP page refreshing test, and then perform the related operations.

You can test the upload state of a WAP page by refreshing the same page many times.

You must perform the Dial Up test before the WAP Page Refresh test.

Property Value/Range/Unit Description

Test Count The value must be a positive integer.
The default value is 10.

Indicates the number of tests.

Test Interval The value must be a positive integer.
The default value is 5. The unit is
second.

Indicates the interval between two
tests.

Timeout The value must be a positive integer.
The default value is 60. The unit is
second.

Indicates the timeout time. The
timing starts when the first gateway
connection request is sent. If the
connection is not set up within the
preset time, you can infer that the
download fails.

Download
Icon

You can select the following values:
l True: downloads icons on the title

page.
l False: not download icons on the

title page.
The default value is True.

Indicates whether to download icons
on the title page.

URL The URL starts with http://. Indicates the URL of the tested
WAP page.

IP Contact local network operators to
obtain the IP address.

Indicates the IP address of the WAP
gateway.

Port The value ranges from 0 to 1023, and
the default value is 80.

Indicates the port number of the
WAP.



NetEntry (WiMAX)

This section describes the properties of the WiMAX NetEntry test item. You can refer to this
section when the Probe performs NetEntry tests.

NetEntry tests are used for measuring the network access performance. Before accessing the
network during a test, the MS must exit from the network.

Property Value/Range/Unit Description

Test Count The default value is 10. Indicates the number of NetEntry tests.

GENEX Probe
User Guide 14 Appendix

Issue 04 (2011-02-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.

14-53

Similer Documents