	Chapter 1 Regulatory Compliance Statement
	Chapter 2 Regulatory Compliance Information
		2.1 Regulatory Compliance Standards
		2.2 European Directives Compliance
		2.3 USA Regulatory Compliance (FCC Part 15)
		2.4 Japan Regulatory Compliance
		2.5 CISPR 22 Compliance
	Chapter 3 Safety Information
		3.1 Overview
			3.1.1 Conventions Used
			3.1.2 General Requirements
		3.2 Electricity Safety
			3.2.1 High Voltage
			3.2.2 Power Cable
			3.2.3 Tools
			3.2.4 Drilling
			3.2.5 Thunderstorm
			3.2.6 Electrostatic
		3.3 Fuse
		3.4 Working at Heights
			3.4.1 The Safety Codes on Ladder-using
			3.4.2 Weight Hoisting
		3.5 Miscellaneous
			3.5.1 Lifting Heavy Objects
			3.5.2 Sharp Objects
			3.5.3 Plug/Unplug Board
			3.5.4 Binding Signal Cables
	Chapter 4 Sicherheitsinformationen
                        
Document Text Contents
Page 1

Chapter 1 Regulatory Compliance Statement 1-1...............................................

Chapter 2 Regulatory Compliance Information 2-1............................................

2.1 Regulatory Compliance Standards 2-1.........................................................
2.2 European Directives Compliance 2-1...........................................................
2.3 USA Regulatory Compliance (FCC Part 15) 2-1..........................................
2.4 Japan Regulatory Compliance 2-2...............................................................
2.5 CISPR 22 Compliance 2-2...........................................................................

Chapter 3 Safety Information 3-1..........................................................................

3.1 Overview 3-1................................................................................................
3.1.1 Conventions Used 3-1..........................................................................
3.1.2 General Requirements 3-2...................................................................

3.2 Electricity Safety 3-3.....................................................................................
3.2.1 High Voltage 3-3..................................................................................
3.2.2 Power Cable 3-3..................................................................................
3.2.3 Tools 3-4..............................................................................................
3.2.4 Drilling 3-4............................................................................................
3.2.5 Thunderstorm 3-5.................................................................................
3.2.6 Electrostatic 3-5...................................................................................

3.3 Fuse 3-6.......................................................................................................
3.4 Working at Heights 3-6.................................................................................

3.4.1 The Safety Codes on Ladder-using 3-7...............................................
3.4.2 Weight Hoisting 3-7..............................................................................

3.5 Miscellaneous 3-8.........................................................................................
3.5.1 Lifting Heavy Objects 3-8.....................................................................
3.5.2 Sharp Objects 3-8................................................................................
3.5.3 Plug/Unplug Board 3-9.........................................................................
3.5.4 Binding Signal Cables 3-9....................................................................

Chapter 4 Sicherheitsinformationen 4-1..............................................................

Page 15

Compliance and Safety Manual
HUAWEI MSOFTX3000 Mobile SoftSwitch Center Chapter 3 Safety Information


Huawei Technologies Proprietary

3-3

3.2 Electricity Safety

3.2.1 High Voltage



Danger:

High voltage power supply offers electric power for equipment operation. Direct contact
or indirect contact (through damp objects) with high voltage and AC mains supply may
result in fatal danger.



During the installation of AC power supply facility, the local safety regulations must
be followed. The personnel who install the AC facility must be qualified for high
voltage and AC operations.

Conductive articles, such as watch, hand chain, bracelet and ring are prohibited
during the operation.

When water is found in the rack, or the rack is damp, immediately switch off the
power supply.

When operation is performed in a damp environment, make sure that water is kept
off the equipment.



Warning:

Non-standard and improper high voltage operations may result in fire and electric
shock. Therefore, when bridging and wiring the AC cable across a certain area, follow
the local rules and regulations. The personnel who perform high voltage operations
should be qualified for high voltage and AC operations.



3.2.2 Power Cable



Note:

Installation and removal of live power cable is prohibited strictly. Transient contact
between the core of power cable and conductor may generate spark or electric arc,
which may lead to fire or eye injury.

Page 16

Compliance and Safety Manual
HUAWEI MSOFTX3000 Mobile SoftSwitch Center Chapter 3 Safety Information


Huawei Technologies Proprietary

3-4

Before the power cable is installed or removed, the power switch must be turned
off.

Before the power cable is connected, it must be confirmed that the power cable
and label comply with the requirements of the actual installation.



Note:

Use power cables, whose cross sections are greater than 25 mm2, to connect the
equipment powered by DC.



3.2.3 Tools



Warning:

During high voltage and AC operations, special tools should be used. It is not permitted
to use common tools or tools brought by the operator.



3.2.4 Drilling



Warning:

Drilling on the rack without permission is strictly prohibited. Drilling that does not satisfy
the requirements concerned may damage the wires and cables inside the rack. If the
metal swarf from the drilling gets into the rack, it may result in short-circuit of the circuit
boards.



If it is necessary to drill a hole on the rack, insulation protection gloves must be
worn, and the cables inside the rack should first be removed.

During the drilling, make sure that the eyes of the operator are well protected. The
spattering swarf may cause injury to the eyes.

Make sure that the metal swarf does not get into the rack.
Non-standard drilling operation may damage the electromagnetic shielding

performance of the rack.

Page 30

Compliance and Safety Manual
HUAWEI MSOFTX3000 Mobile SoftSwitch Center Chapter 4 Sicherheitsinformationen


Huawei Technologies Proprietary

4-9



Figure 4-2 Lastenaufzug

4.5 Sonstiges

4.5.1 Anheben schwerer Gegenstände



Warnung:

Es ist verboten, unter einem angehobenen Gegenstand zu stehen oder durchzulaufen.



4.5.2 Scharfkantige Gegenstände



Warnung:

Um sich vor Verletzungen zu schützen dürfen scharfkantige Gegenstände nur mit

Schutzhandschuhen angefasst und transportiert warden .

Page 31

Compliance and Safety Manual
HUAWEI MSOFTX3000 Mobile SoftSwitch Center Chapter 4 Sicherheitsinformationen


Huawei Technologies Proprietary

4-10

4.5.3 Einsteckplatinen



Anmerkung:

Beim Einstecken einer Platine darf kein zu großer Druck ausgeübt werden, ansonsten
kann es zur Verdrehung der Kontakte kommen .



Die Platine muss exakt längs zum Einschub eingeführt werden. Verhindern Sie,
dass sich die Schaltkreise der Platinen berühren. Das kann zu Kurzschluss oder
Kratzern auf der Platine führen.

Berühren Sie nicht mit den Fingern die Schaltkreise, Einzelkomponenten,
Verbindungen und Verbindungsschlitze.

4.5.4 Zusammenlegen von Signalleitungen



Anmerkung:

Signalleitungen sollten getrennt von Hochspannungsleitungen verlegt warden . Der
Abstand zwischen den Leitungen sollte mindestens 150mm betragen .

Similer Documents